This will allow your water heater to operate efficiently and effectively and most significantly it will avoid any probability of danger and therefore the risk of carbon monoxide gas poisoning.
Venting water heater through roof.
Tankless water heaters can vent through the roof or a side wall creating more flexibility and options for placement.
Use a plumb bob to be sure the center of the tube at the.
In order to do this two critical measurements must be taken.
Go into your attic.
With the pipe in a vertical position trace around the pipe using a pencil.
Mark the ceiling above the water heater to receive the pipe.
One on the ceiling above the water heater and one that is the distance from the attic floor to the roof.
Atmospheric venting refers to a system in which exhaust from the water heater naturally rises out of the appliance s combustion chamber then travels up through a standard chimney style flue that.
If it is a natural vent type water heater you can not vent it through the side wall it has to vent above the roof.
Illustrations of proper gas fired water heater venting using type b double wall vent pipe through a roof above or through a chimney below include details for the flue vent connector such as the requirement of a minimum vent connector upwards slope of 1 4 per foot of horizontal run.
Position the vent pipe up to the bottom of the roof.
In the attic use the plumb bob to mark the center of the hole to be cut for the roof.
Tankless water heaters use fans to blow exhaust from the unit horizontally allowing vents to terminate on the side of a house.
Traditional gas tank water heater require venting through the roof.
Direct vent water heaters.
Other issue is the bathroom installation which isn t permitted as well unless the water heater closet is sealed from the bathroom area air tight doors and it has a separate fresh air supply from exterior or other areas of the house that can be used for this purpose.
When installing a gas water heater building codes requires that they be ventilated out of the room through the attic and out through the roof.
Cut the hole with the jigsaw.
Exhaust gases are vented outdoors through a separate vent duct or through a separate chamber of the same pipe this requires a double wall vent duct.
With a direct vent system air for combustion is drawn from a vent pipe that runs through an exterior wall or the roof.