These valves are gravity operated devices that respond to the negative pressure of draining water and open to let air in.
Vent toilet with air admittance valve.
Air admittance valves aav are one way vents installed after the trap on the drain line of a fixture.
The device shall close by gravity and seal the vent terminal at zero differential pressure no flow conditions and under positive internal pressures.
After a toilet flushes the increased water flowing down the drain creates a negative pressure.
This negative pressure causes the vent to open and let in enough air to relieve the pressure.
If you re wondering how studor vents work after the toilet is flushed the water flows down the drain resulting in negative pressure.
To finish the job successfully you will need a tee sanitarian pipe.
Stack type air admittance valves shall be located not less than 6 inches 152 mm above the flood level rim of the highest fixture being vented.
The negative pressure activated one way vents to protect the trap seals in the drainage system by allowing the intake of air so that the right level of pressure within the drainage system is maintained.
Studor a brand name air admittance valve can solve venting problems when open air venting pipes will not work.
They re designed to address negative air pressure in the drain system created when a fixture is drained.
Since you want to install it to vent the toilet the best solution is to attach the system to the toilet drain.
Studor vents allow air to enter the pipes while keeping sewer gasses or odor from escaping.
After allowing air in it seals itself back up to keep odors and gasses out.
An air admittance valve is a 1 way valve designed to allow air to enter the plumbing drainage system when negative pressures develop in the piping system.
More product details close.
Individual and branch air admittance valves shall be located not less than 4 inches 102 mm above the horizontal branch drain or fixture drain being vented.
World leading air admittance valves.
Studor vent studor vents are a very popular kind of air admittance valve that works really well.
Keep in mind that you need to install air admittance valve at least 4 inches 10 cm higher than a drain line.
In the event that your walls do not leave enough space for any of the above vents then the local code may allow you to opt for an air admittance valve aav.
Then gravity closes the valve keeping sewer gases out of the room.
This one way valve is designed to allow air into the plumbing when negative pressure is developed from draining.